Customer case · Malaysia

PTFE-Coated B7 Stud Bolts for a Malaysian Petrochemical Plant

A petrochemical plant in Malaysia sent a mixed list of flange stud bolt sizes. HEXVARO supplied ASTM A193 Grade B7 full-thread studs, each with two ASTM A194 Grade 2H heavy hex nuts, coated with zinc-nickel plating under a PTFE topcoat, and shipped the order by container.

  • StatusShipped
  • DestinationMalaysia · petrochemical
  • Sizes1/2 in – 2-1/2 in
  • CoatingZn-Ni + PTFE

Order summary

Customer
Petrochemical plant, Malaysia (name withheld)
Product
ASTM / ASME SA-193 Grade B7 full-thread stud bolts
Nuts
ASTM / ASME SA-194 Grade 2H heavy hex, two per stud
Supply form
Sets of one stud and two nuts, supplied unassembled
Sizes
1/2 in to 2-1/2 in diameter, 60 to 680 mm long
Threads
UNC up to 7/8 in; 8UN from 1-1/8 in
Coating
Zinc-nickel electroplating, 10–15 µm, with a PTFE topcoat
Packing
Each stud in a plastic net sleeve; studs and bagged nuts in cartons
Shipment
Sea freight by container, China to Malaysia
Status
Shipped

Quantities and prices stay between HEXVARO and the customer.

Photographs from this order

Tap a photo to open it full size.

What the buyer asked for

  • Sets for flange bolting: one B7 full-thread stud with two 2H heavy hex nuts, not assembled.
  • A mixed size list in one order, from 1/2 in UNC studs up to 2-1/2 in 8UN studs.
  • A two-layer corrosion protection system: zinc-nickel electroplating of 10–15 µm under a PTFE topcoat.
  • Packing that keeps the coated threads from rubbing in transit.

Sizes on the order

Selected lines. Length in millimetres; each line supplied as sets of one stud and two heavy hex nuts.

Diameter – TPISeriesLengths (mm)
1/2 in-13UNC60, 65, 70, 85
5/8 in-11UNC85, 90, 110, 120, 180
3/4 in-10UNC110, 115, 120, 130
7/8 in-9UNC115, 130, 150
1-1/8 in-88UN150, 205
1-5/8 in-88UN210, 300, 440, 680
2-1/2 in-88UN440

Details that mattered

01

Why 8UN on the large sizes

ASME B16.5 flange studs of 1-1/8 in and above normally use the 8-thread series (8UN) rather than the coarser UNC pitch. A mixed list therefore carries two thread series, and both have to be gauged.

02

Why zinc-nickel under PTFE

The zinc-nickel layer gives the steel sacrificial corrosion protection. The PTFE topcoat adds a barrier layer, gives the colour, and lowers thread friction. Because the coating changes friction, tightening torque should follow the project procedure or the coating supplier's nut factor, not a dry-thread torque table.

03

Why net sleeves

Coated studs packed loose rub against each other and damage the coating on the thread crests. Each stud went into its own plastic net sleeve before boxing; the nuts were bagged and boxed separately.

Similar list?

Send your stud bolt list.
We reply within 2 working hours.

Grade, diameter and thread series, length, nuts per stud, coating and quantity per line. MOQ 500 pcs per specification.